! Temperature Flight Planning Table temper21.rdf 17-Jul-2015 Temperature Flight Planning Table Version (-) = 0.99-20061109 Number of Cooling Zones (-) = 4 ! Nz Baseline Antenna Duty Cycle (-) = 100.0 ! % Max heater pwr Minimum Antenna Duty Cycle (-) = 100.0 ! % Max heater pwr ! It is assumed that the cooling zones are numbered from 1, ..., Nz. ! One block of parameters is defined for each cooling zone. ! The value of Nzone is embedded within each RDF keyword. ! Zone 1 is used for electronics not connected to a cooling duct and for electronics on the Slave pod electronics cooling duct Zone 1 Type (-) = 2 ! ZoneType = 2 = electronics, = 0 = disable Zone 1 Antenna Number (-) = 0 ! Nantenna Zone 1 Control Temperature Maximum (-) = 31815 ! Thi - not used Zone 1 Control Temperature Minimum (-) = 27815 ! Tlo - not used Zone 1 Upper Red Region Width (-) = 1000 ! dTru - not used Zone 1 Lower Red Region Width (-) = 500 ! dTrl - not used Zone 1 Upper Yellow Region Width (-) = 500 ! dTyu - not used Zone 1 Lower Yellow Region Width (-) = 500 ! dTyl - not used Zone 1 Inlet Air Temperature Sensor Count (-) = 0 ! Nair Zone 1 Control Temperature Sensor Count (-) = 0 ! Ncont Zone 1 Monitor Temperature Sensor Count (-) = 2 ! Nmon Zone 1 Monitor Temperature Sensor 1 (-) = 19 ! Battery Zone 1 Monitor Temperature Sensor 1 Heater (-) = 5 Zone 1 Monitor Temperature Sensor 1 Maximum (-) = 30315 ! Tmax, +30 C (Heater turns off.) Zone 1 Monitor Temperature Sensor 1 Minimum (-) = 26315 ! Tmin, -10 C (Heater turns on.) Zone 1 Monitor Temperature Sensor 2 (-) = 4 ! DGPS slave pod Zone 1 Monitor Temperature Sensor 2 Heater (-) = 8 Zone 1 Monitor Temperature Sensor 2 Maximum (-) = 30315 ! Tmax, +30 C (Heater turns off.) Zone 1 Monitor Temperature Sensor 2 Minimum (-) = 27315 ! Tmin, +0 C (Heater turns on.) ! Zone 2 contains all the electronics on the electronics cooling duct in the master pod Zone 2 Type (-) = 2 ! ZoneType = 2 = electronics, = 0 = disable Zone 2 Antenna Number (-) = 0 ! Nantenna Zone 2 Control Temperature Maximum (-) = 31815 ! Thi, +45 C [Green = +25 - +35] Zone 2 Control Temperature Minimum (-) = 28815 ! Tlo, +15 C Zone 2 Upper Red Region Width (-) = 500 ! dTru, upper red > +40 Zone 2 Lower Red Region Width (-) = 500 ! dTrl, lower red < +20 Zone 2 Upper Yellow Region Width (-) = 500 ! dTyu, upper ylw +35 - +40 Zone 2 Lower Yellow Region Width (-) = 500 ! dTyl, lower ylw +20 - +25 Zone 2 Inlet Air Temperature Sensor Count (-) = 2 ! Nair Zone 2 Inlet Air Temperature Sensor 1 (-) = 8 ! Nambient Zone 2 Inlet Air Temperature Sensor 2 (-) = 9 Zone 2 Control Temperature Sensor Count (-) = 4 ! Ncont Zone 2 Control Temperature Sensor 1 (-) = 11 ! Ncontrol Digital VME Zone 2 Control Temperature Sensor 1 Heater (-) = 1 ! Nconhtr Heater #1 to enable Zone 2 Control Temperature Sensor 2 (-) = 32 ! PDU Zone 2 Control Temperature Sensor 2 Heater (-) = 6 Zone 2 Control Temperature Sensor 3 (-) = 13 ! RF VME Zone 2 Control Temperature Sensor 3 Heater (-) = 2 ! Heater #2 to enable Zone 2 Control Temperature Sensor 4 (-) = 16 ! DGPS Zone 2 Control Temperature Sensor 4 Heater (-) = 3 Zone 2 Monitor Temperature Sensor Count (-) = 4 ! Nmon Zone 2 Monitor Temperature Sensor 1 (-) = 12 ! Nmonitor Digital VME Zone 2 Monitor Temperature Sensor 1 Heater (-) = 1 ! Nmonhtr Heater #1 to enable Zone 2 Monitor Temperature Sensor 1 Maximum (-) = 31815 ! Tmax, +45 C Zone 2 Monitor Temperature Sensor 1 Minimum (-) = 25815 ! Tmin, -15 C Zone 2 Monitor Temperature Sensor 2 (-) = 31 ! PDU Zone 2 Monitor Temperature Sensor 2 Heater (-) = 6 Zone 2 Monitor Temperature Sensor 2 Maximum (-) = 31815 ! Tmax, +45 C Zone 2 Monitor Temperature Sensor 2 Minimum (-) = 25815 ! Tmin, -15 C Zone 2 Monitor Temperature Sensor 3 (-) = 14 ! RF VME Zone 2 Monitor Temperature Sensor 3 Heater (-) = 2 ! Heater #2 to enable Zone 2 Monitor Temperature Sensor 3 Maximum (-) = 31315 ! Tmax, +40 C Zone 2 Monitor Temperature Sensor 3 Minimum (-) = 25815 ! Tmin, -15 C Zone 2 Monitor Temperature Sensor 4 (-) = 15 ! DGPS Zone 2 Monitor Temperature Sensor 4 Heater (-) = 3 Zone 2 Monitor Temperature Sensor 4 Maximum (-) = 31815 ! Tmax, +45 C Zone 2 Monitor Temperature Sensor 4 Minimum (-) = 26815 ! Tmin, -5 C ! Zone 3 is the L-band antenna cooling duct in the master pod Zone 3 Type (-) = 0 ! ZoneType = 1 = antenna, 0 = disable Zone 3 Antenna Number (-) = 1 ! antenna #1 Zone 3 Control Temperature Maximum (-) = 30815 ! Thi, +35 C [Green -5 - +5] Zone 3 Control Temperature Minimum (-) = 23815 ! Tlo, -35 C Zone 3 Upper Red Region Width (-) = 500 ! dTru, upper red > +30 Zone 3 Lower Red Region Width (-) = 500 ! dTrl, lower red < -30 Zone 3 Upper Yellow Region Width (-) = 2500 ! dTyu, upper ylw +5 - +30 Zone 3 Lower Yellow Region Width (-) = 2500 ! dTyl, lower ylw -30 - -5 Zone 3 Inlet Air Temperature Sensor Count (-) = 0 ! Nair Zone 3 Control Temperature Sensor Count (-) = 3 ! Ncont Zone 3 Control Temperature Sensor 1 (-) = 22 Zone 3 Control Temperature Sensor 1 Heater (-) = 9 Zone 3 Control Temperature Sensor 2 (-) = 23 Zone 3 Control Temperature Sensor 2 Heater (-) = 9 Zone 3 Control Temperature Sensor 3 (-) = 24 Zone 3 Control Temperature Sensor 3 Heater (-) = 9 Zone 3 Monitor Temperature Sensor Count (-) = 3 ! Nmon Zone 3 Monitor Temperature Sensor 1 (-) = 22 Zone 3 Monitor Temperature Sensor 1 Heater (-) = 9 Zone 3 Monitor Temperature Sensor 1 Maximum (-) = 30815 ! Tmax, +35 C Zone 3 Monitor Temperature Sensor 1 Minimum (-) = 23815 ! Tmin, -35 C Zone 3 Monitor Temperature Sensor 2 (-) = 23 Zone 3 Monitor Temperature Sensor 2 Heater (-) = 9 Zone 3 Monitor Temperature Sensor 2 Maximum (-) = 30815 ! Tmax, +35 C Zone 3 Monitor Temperature Sensor 2 Minimum (-) = 23815 ! Tmin, -35 C Zone 3 Monitor Temperature Sensor 3 (-) = 24 Zone 3 Monitor Temperature Sensor 3 Heater (-) = 9 Zone 3 Monitor Temperature Sensor 3 Maximum (-) = 30815 ! Tmax, +35 C Zone 3 Monitor Temperature Sensor 3 Minimum (-) = 23815 ! Tmin, -35 C ! Zone 4 is the L-band antenna cooling duct in the slave pod Zone 4 Type (-) = 1 ! ZoneType = 1 = antenna Zone 4 Antenna Number (-) = 2 ! antenna #2 Zone 4 Control Temperature Maximum (-) = 30815 ! Thi, +35 C [Green -5 - +5] Zone 4 Control Temperature Minimum (-) = 23815 ! Tlo, -35 C Zone 4 Upper Red Region Width (-) = 500 ! dTru, upper red > +30 Zone 4 Lower Red Region Width (-) = 500 ! dTrl, lower red < -30 Zone 4 Upper Yellow Region Width (-) = 2500 ! dTyu, upper ylw +5 - +30 Zone 4 Lower Yellow Region Width (-) = 2500 ! dTyl, lower ylw -30 - -5 Zone 4 Inlet Air Temperature Sensor Count (-) = 0 ! Nair Zone 4 Control Temperature Sensor Count (-) = 3 ! Ncont Zone 4 Control Temperature Sensor 1 (-) = 26 Zone 4 Control Temperature Sensor 1 Heater (-) = 10 Zone 4 Control Temperature Sensor 2 (-) = 27 Zone 4 Control Temperature Sensor 2 Heater (-) = 10 Zone 4 Control Temperature Sensor 3 (-) = 28 Zone 4 Control Temperature Sensor 3 Heater (-) = 10 Zone 4 Monitor Temperature Sensor Count (-) = 3 ! Nmon Zone 4 Monitor Temperature Sensor 1 (-) = 26 Zone 4 Monitor Temperature Sensor 1 Heater (-) = 10 Zone 4 Monitor Temperature Sensor 1 Maximum (-) = 30815 ! Tmax, +35 C Zone 4 Monitor Temperature Sensor 1 Minimum (-) = 23815 ! Tmin, -35 C Zone 4 Monitor Temperature Sensor 2 (-) = 27 Zone 4 Monitor Temperature Sensor 2 Heater (-) = 10 Zone 4 Monitor Temperature Sensor 2 Maximum (-) = 30815 ! Tmax, +35 C Zone 4 Monitor Temperature Sensor 2 Minimum (-) = 23815 ! Tmin, -35 C Zone 4 Monitor Temperature Sensor 3 (-) = 28 Zone 4 Monitor Temperature Sensor 3 Heater (-) = 10 Zone 4 Monitor Temperature Sensor 3 Maximum (-) = 30815 ! Tmax, +35 C Zone 4 Monitor Temperature Sensor 3 Minimum (-) = 23815 ! Tmin, -35 C ! End of table